Fully Non-Linear Numerical Simulation of a Shaking Table Test of Dynamic Soil-Pile-Structure Interactions in Soft Clay Using ABAQUS Geo-Congress 2019 10.1061/9780784482100.026
1.4.2 ANCO-Model R150.142 shaking table This servo-hydraulic type-shaking table was used by Columbia University. It is a medium scale shaking table facility to conduct experimentation in …
2020101· A numerical model of the shaking table system is developed in MATLAB/Simulink to simulate the environment in which the RL controller will interact and …
202541· For the shaking table model tests, a cut slope along the Sanbao–Qingshui Expressway (located between Qujing City and Kunming City) was selected as the prototype. …
201941· A series of 1-g shaking table tests using variable-amplitude harmonic excitations was performed on 0.8-m-high MSE/soil nail hybrid retaining (MSE/SN) wall models to …
In this paper, a series of 1-g shaking table model tests were carried out to investigate the seismic behavior of a relatively stiff rectangular tunnel structure installed in soft clay bed, accounting …
202441· In the present study, a series of shaking table model tests were performed on a slope with a gabion reinforced retaining wall. Transfer functions were employed to compute …
2025110· In order to solve the factors affecting the modeling of seismic shaking table array system, the transfer function of two-array system under three-parameter and multi-parameter …
2015107· Quick Search anywhere. Enter Search Term. Quick Search in Journals
2015630· Shaking tables provide one means of obtaining data from physical models of geotechnical systems under simulated earthquake loading. While there may be challenges in …
202561· Piezoelectric acceleration sensors are placed on the surface of the shaking table and on each floor of the model. To account for their measurement direction, the sensors are …
2020101· A numerical model of the shaking table system is developed in MATLAB/Simulink to simulate the environment in which the RL controller will interact and …
202558· 2.1 Shaking Table and Model Box Parameters. The shaking table test was conducted using a two-degree-of-freedom electro-hydraulic servo earthquake simulator from …
Based on the shaking table test of the underground two-hole loess cave dwelling, the numerical model of three-dimensional ULC was established by using ABAQUS software. The numerical …
201361· Two physical models, consisting of a shallow foundation resting on a sand deposit, are tested on a shaking table to analyse soil–foundation interaction. The physical …
202061· The FE model is shown to compare adequately well with the shaking table tests. The validated FE model is used to predict the seismic response of the prototype, thus allowing …
2024111· Subsequently, a series of shaking table model tests were conducted to examine the time-domain and frequency-domain dynamic responses of slopes to near-fault ground …
2024712· Multiple sets of shaking table model tests of anchored slopes under the excitation of El Centro, Landers and sine waves were carried out. The effect of the type and frequency of seismic waves on the dynamic response …
2008111· The shaking table is an essential testing tool in the development of earthquake resistant buildings and infrastructure, so improving its performance is an important contribution …
830· The shaking table for different dynamic input parameters, such as acceleration amplitude, wave frequency and waveform was conducted to study the dynamic response …
200551· Physical model experiments were performed on a 1 𝑔 shaking table with the principal goals of: (1) investigating the mechanisms of seismically induced permanent …
20191129· In this experimental study, shaking table tests are performed on 2×2 symmetrical pile groups with different rake angles 0°, 15°, and 25°. The dynamic response of …
In order to solve the factors afecting the modeling of seismic shaking table array system, the transfer function of two-array system under three-parameter and multi-parameter control is …
927· The common arrangement of additional mass blocks in UST model tests: (A) At the top of model, 27 (B) along the length of the model without intervals, 33 and (C) along the …
2013121· Additionally, the polystyrene was laid along the inner side of model box to reduce or avoid the wave reflection in shaking table test [27, 28]. The model of anchoring …
202541· For the shaking table model tests, a cut slope along the Sanbao–Qingshui Expressway (located between Qujing City and Kunming City) was selected as the prototype. …